1-Bromopropane WEL 0.5 mg/m³ (0.1 ppm) — monitoring strategy and interpretation

1-Bromopropane is a new airborne contaminant with an 8-hour WEL of 0.5 mg/m³ (0.1 ppm). WES remains the reference until 30 November 2026; from 1 December 2026 WEL applies once implemented—verify with your WHS regulator. SEGs and sampling Vapour degreaser operators: load/unload, lid opening and warm parts. Cold cleaning, wipe/spray, formulation, laboratory/QC, maintenance and waste. […]

1-Bromopropane WEL 0.5 mg/m³ (0.1 ppm) — monitoring strategy and interpretation Read More »

RCS in tunnelling — full-shift monitoring, SEGs and interpreting 0.05 mg/m³

**Respirable crystalline silica (RCS)** remains on Australia’s Workplace Exposure Limits list at **0.05 mg/m³** (respirable). On **1 December 2026**, RCS is in the **held / nine carve-out** set — it does **not** tighten to **0.025 mg/m³** that day. Until **30 November 2026**, apply the current WES regime. From **1 December 2026**, apply WEL once implemented

RCS in tunnelling — full-shift monitoring, SEGs and interpreting 0.05 mg/m³ Read More »

DPM in tunnelling — elemental carbon monitoring and interpreting 0.01 mg/m³

**Diesel particulate matter (DPM)** enters Australia’s Workplace Exposure Limits list as a **new** airborne contaminant with an 8-hour TWA of **0.01 mg/m³** as **respirable elemental carbon (EC)**. There was **no previous SWA WES** for this listing. Until **30 November 2026**, apply the current WES regime and manage risk SFARP. From **1 December 2026**, apply the

DPM in tunnelling — elemental carbon monitoring and interpreting 0.01 mg/m³ Read More »

Bisphenol-A WEL 2 mg/m³ — fraction, method cues and result interpretation

Bisphenol-A is a new airborne listing with an 8-hour WEL of 2 mg/m³. Until 30 November 2026, apply WES; from 1 December WEL applies once implemented. Confirm timing with the WHS regulator. Do not invent ppm or a STEL. Characterise the aerosol Exposure profiles include powder handling (bag tip, weigh, blend, mill), heated resin/process fume,

Bisphenol-A WEL 2 mg/m³ — fraction, method cues and result interpretation Read More »

Benzoyl chloride WEL 2.8 mg/m³ (0.5 ppm) — monitoring strategy and interpretation

Benzoyl chloride is a volatile, reactive acyl chloride with a new 8-hour WEL of 2.8 mg/m³ (0.5 ppm). WES remains the reference until 30 November 2026; WEL applies from 1 December once implemented. Check the WHS regulator. Measurement and SEGs Exposure is typically vapour, with aerosol possible during spraying, vigorous transfer or containment failures. Define

Benzoyl chloride WEL 2.8 mg/m³ (0.5 ppm) — monitoring strategy and interpretation Read More »

Respirable barium sulfate WEL 1.35 mg/m³ — fraction, method and interpretation

From 1 December 2026, once WEL are implemented, respirable barium sulfate carries an 8-hour TWA of 1.35 mg/m³. Inhalable barium sulfate is separate. Until 30 November 2026, apply WES and confirm commencement with the WHS regulator. Fraction and SEGs Respirable sampling answers 1.35 mg/m³; inhalable sampling answers another listing. Define SEGs by powder intensity, record

Respirable barium sulfate WEL 1.35 mg/m³ — fraction, method and interpretation Read More »

What to Do After a Positive Meth Test: Step-by-Step Guide for Australian Property Owners

You’ve just received a meth test report and the results show contamination above the 0.5 µg/100cm² threshold. It’s a stressful moment — but it’s not a crisis. Meth contamination is a fixable problem, and there is a clear, well-established process for addressing it. What matters now is that you move methodically through the right steps,

What to Do After a Positive Meth Test: Step-by-Step Guide for Australian Property Owners Read More »

Meth Testing Hobart: Professional Property Inspections in Tasmania

Hobart’s tight rental market and active property investment scene make meth testing an essential part of due diligence for landlords, buyers, and property managers across the city. Methamphetamine contamination is an invisible hazard — it leaves no visible trace, no odour, and no warning — and it’s more widespread in Tasmania’s rental stock than most

Meth Testing Hobart: Professional Property Inspections in Tasmania Read More »

Meth Testing Adelaide: NATA-Accredited Testing for SA Properties

If you own, manage, or are buying property in Adelaide, meth testing is one of the most important due diligence steps you can take. South Australia’s property market is active and competitive — and methamphetamine contamination is invisible, odourless, and more common than most buyers and landlords realise. Anitech Group provides professional, NATA-accredited meth testing